Insulin Correction & Sensitivity Calculator

Calculates insulin sensitivity factor, correction dose, and I:C ratio

Calculator

Loading calculator…

Why use it

Personalizes insulin dosing. Calculates how much 1 unit of insulin will lower blood glucose. Determines correction doses for hyperglycemia. Estimates carb coverage ratios.

About

Calculates the Insulin Sensitivity Factor (ISF/correction factor) using the 1800 rule (rapid-acting) or 1500 rule (regular insulin), the correction dose for hyperglycemia, and the Insulin-to-Carb (I:C) ratio using the 500 rule. These calculations are fundamental to diabetes management for both insulin pump users and MDI (multiple daily injection) patients.

When to use

  • Setting up insulin pump parameters
  • Initiating or adjusting MDI (basal-bolus) regimens
  • Calculating correction doses for hyperglycemia
  • Adjusting insulin-to-carb ratios

Formula

ISF (mg/dL per unit) = 1800 / TDD (rapid-acting) ISF = 1500 / TDD (regular insulin) Correction dose (units) = (Current BG - Target BG) / ISF I:C ratio = 500 / TDD (grams carb per 1 unit)

Pearls & pitfalls

  • 1800 Rule (rapid-acting: lispro, aspart, glulisine): ISF = 1800 / TDD.
  • 1500 Rule (regular insulin): ISF = 1500 / TDD.
  • 500 Rule (I:C ratio): I:C = 500 / TDD (grams of carb per 1 unit).
  • TDD = Total Daily Dose of all insulin (basal + bolus).
  • These are STARTING estimates — always individualize based on monitoring.
  • ISF typically ranges from 20-100 mg/dL per unit in adults.
  • Sick patients, steroid use, and stress can significantly alter insulin sensitivity.

Next steps

ISF and I:C ratios are starting estimates — titrate based on glucose monitoring (CGM or SMBG). Correction dose = (Current BG - Target BG) / ISF. Review every 1-2 weeks during initiation. Always consider active insulin on board (IOB).

Evidence

The 1800 rule (Walsh et al., Pumping Insulin) and 500 rule are widely used in clinical practice and ADA/AACE guidelines. Evidence is largely empirical and consensus-based. Individualization through glucose monitoring is always required.

References

  1. Walsh J, Roberts R. Pumping Insulin. 6th ed. Torrey Pines Press; 2016. — link
  2. American Diabetes Association. Standards of Care in Diabetes — 2024. Diabetes Care. 2024;47(Suppl 1). — link